<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">genort</journal-id><journal-title-group><journal-title xml:lang="ru">Гений ортопедии</journal-title><trans-title-group xml:lang="en"><trans-title>Genij Ortopedii</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1028-4427</issn><issn pub-type="epub">2542-131X</issn><publisher><publisher-name>ЦЕНТР ИЛИЗАРОВА</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">genort-433</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Оригинальные статьи</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Original articles</subject></subj-group></article-categories><title-group><article-title>Данные сонографического и оптико-денситометрического исследования дистракционного регенерата при удлинении плечевой кости у детей больных ахондроплазией</article-title><trans-title-group xml:lang="en"><trans-title>Data of sonographic and opticodensitometric studies of distraction regenerate in the process of humeral elongation in children with achondroplasia</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Ермак</surname><given-names>Е. М.</given-names></name></name-alternatives><email xlink:type="simple"></email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Климов</surname><given-names>О. В.</given-names></name></name-alternatives><email xlink:type="simple"></email></contrib></contrib-group><pub-date pub-type="collection"><year>1999</year></pub-date><pub-date pub-type="epub"><day>28</day><month>03</month><year>1999</year></pub-date><volume>0</volume><issue>1</issue><issue-title>№ 1 (1999)</issue-title><elocation-id>433</elocation-id><permissions><copyright-statement>Copyright &amp;#x00A9; Ермак Е., Климов О., 1999</copyright-statement><copyright-year>1999</copyright-year><copyright-holder xml:lang="ru">Ермак Е., Климов О.</copyright-holder><copyright-holder xml:lang="en">Ермак Е., Климов О.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.ilizarov-journal.com/jour/article/view/433">https://www.ilizarov-journal.com/jour/article/view/433</self-uri><abstract><p>Результаты исследований показали возможность объективной оценки как плотности, так и структуры дистракционного регенерата при ультросонографическом исследовании удлиняемой кости. При этом контроль за процессом регенерации возможен уже с первых дней дистракции, когда регенерат еще рентгенонегативен. Проведены параллельно исследования рентгенологического изображения удлиняемого сегмента на комплексе ДиаМорф - Cito позволили провести параллель между данными сонографии и рентгенологического исследования, а также изучить динамику изменения оптической плотности различных участков регенерата и изменение соотношения структур, образующих исходное его изображение.</p></abstract><trans-abstract xml:lang="en"><p>Results of the studies demonstrated the possibility of impartial assessment of both density and structure of distraction regenerate during ultrasonographic study of the bone being elongated. Moreover, control of the regeneration process had been possible just from the first days of distraction, when the regenerate is roentgen-negative. A parallel studies of elongated segment X-ray, using DiaMorph-Cito complex, gave the possibility to investigate the dynamics of optical density changes in different parts of the regenerate and correlation change of the structures, forming the regenerate initial image, as well as to draw a parallel between the data of sonography and those of roentgenologic study.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>коленный сустав</kwd><kwd>артроскопия</kwd><kwd>болезнь Гоффа</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
