<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">genort</journal-id><journal-title-group><journal-title xml:lang="ru">Гений ортопедии</journal-title><trans-title-group xml:lang="en"><trans-title>Genij Ortopedii</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1028-4427</issn><issn pub-type="epub">2542-131X</issn><publisher><publisher-name>ЦЕНТР ИЛИЗАРОВА</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">genort-400</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Новые технологии</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>New technologies</subject></subj-group></article-categories><title-group><article-title>Устройство для устранения порочного положения голени при аплазии большеберцовой кости</article-title><trans-title-group xml:lang="en"><trans-title>The Device for Correction of Tibial Mal-Position in Tibial Aplasia</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Макушин</surname><given-names>В. Д.</given-names></name></name-alternatives><email xlink:type="simple"></email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Чегуров</surname><given-names>О. К.</given-names></name></name-alternatives><email xlink:type="simple"></email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Коваленко</surname><given-names>Т. Н.</given-names></name></name-alternatives><email xlink:type="simple"></email></contrib></contrib-group><pub-date pub-type="collection"><year>1998</year></pub-date><pub-date pub-type="epub"><day>28</day><month>09</month><year>1998</year></pub-date><volume>0</volume><issue>3</issue><issue-title>№ 3 (1998)</issue-title><elocation-id>400</elocation-id><permissions><copyright-statement>Copyright &amp;#x00A9; Макушин В., Чегуров О., Коваленко Т., 1998</copyright-statement><copyright-year>1998</copyright-year><copyright-holder xml:lang="ru">Макушин В., Чегуров О., Коваленко Т.</copyright-holder><copyright-holder xml:lang="en">Макушин В., Чегуров О., Коваленко Т.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.ilizarov-journal.com/jour/article/view/400">https://www.ilizarov-journal.com/jour/article/view/400</self-uri><abstract><p>Устройство для устранения порочного положения голени собирается из стандартных деталей аппарата Илизарова и содержит в себе три функциональных модуля, соответственно установленных на бедре, голени, стопе. Модули устройства соединены между собой  посредством шарнирных узлов, вокруг осей вращения которых происходит исправление порочного положения голени и стопы. Данное устройство применено при лечении 14 пациентов с аплазией большеберцовой кости. При сравнении с современными методами лечения данной  патологии разработанный нами способ лечения и устройство для его осуществления показали высокую их эффективность - 93,8%, с сокращением срока реабилитации в 1,5 - 2 раза.</p></abstract><trans-abstract xml:lang="en"><p>The device for correction of tibial mal-position is assembled from standart parts of Ilizarov apparatus and comprises three functional modules placed in femur, tibia and foot accordingly. The modules of the device are connected with hinge junctions and the mal-position of tibia and foot is corrected around the axes of hinge rotation. The device was applied in management of 14 patients with tibial aplasia. Developed technique of treatment and its device have shown their high efficacy - 93,8% with reduction of rehabilitation duration by 1,5-2 times - in comparison with modern methods of this pathology management.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>бедренная кость</kwd><kwd>костная ткань</kwd><kwd>минеральная плотность</kwd><kwd>физиологические колебания ПМПКТ</kwd><kwd>двухэнергетическая рентгеновская абсорбциометрия</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
