<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">genort</journal-id><journal-title-group><journal-title xml:lang="ru">Гений ортопедии</journal-title><trans-title-group xml:lang="en"><trans-title>Genij Ortopedii</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1028-4427</issn><issn pub-type="epub">2542-131X</issn><publisher><publisher-name>ЦЕНТР ИЛИЗАРОВА</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.18019/1028-4427-2019-25-1-102-110</article-id><article-id custom-type="elpub" pub-id-type="custom">genort-2438</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Обзор литературы</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Literature review</subject></subj-group></article-categories><title-group><article-title>Методология видеоанализа в диагностике нарушений локомоторной функции у детей с церебральным параличом при использовании ограниченного числа светоотражающих камер (обзор литературы)</article-title><trans-title-group xml:lang="en"><trans-title>Optimising video-based data capture for pathological gait analysis in children with cerebral palsy using a limited number of retro-reflective cameras (literature review)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Аксенов</surname><given-names>А.Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Aksenov</surname><given-names>A.Yu.</given-names></name></name-alternatives><email xlink:type="simple">a.aksenov@hotmail.com</email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Хит</surname><given-names>Г.Х.</given-names></name><name name-style="western" xml:lang="en"><surname>Heath</surname><given-names>G.H.</given-names></name></name-alternatives><email xlink:type="simple">glynharveyheath@gmail.com</email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Клишковская</surname><given-names>Т.А.</given-names></name><name name-style="western" xml:lang="en"><surname>Klishkovskaya</surname><given-names>T.A.</given-names></name></name-alternatives><email xlink:type="simple">tatianaklishkov@mail.ru</email></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Долганова</surname><given-names>Т.И.</given-names></name><name name-style="western" xml:lang="en"><surname>Dolganova</surname><given-names>T.I.</given-names></name></name-alternatives><email xlink:type="simple">rjik532007@rambler.ru</email></contrib></contrib-group><pub-date pub-type="collection"><year>2019</year></pub-date><pub-date pub-type="epub"><day>28</day><month>03</month><year>2019</year></pub-date><volume>25</volume><issue>1</issue><issue-title>№ 1 (2019)</issue-title><fpage>102</fpage><lpage>110</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Аксенов А., Хит Г., Клишковская Т., Долганова Т., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Аксенов А., Хит Г., Клишковская Т., Долганова Т.</copyright-holder><copyright-holder xml:lang="en">Aksenov A., Heath G., Klishkovskaya T., Dolganova T.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.ilizarov-journal.com/jour/article/view/2438">https://www.ilizarov-journal.com/jour/article/view/2438</self-uri><abstract><p>Представлен обзор литературы, касающейся методики проведения клинического видеоанализа походки, которая на сегодняшний день является «золотым» стандартом в диагностике и лечении людей с функциональными нарушениями опорно-двигательного аппарата. По данным литературы сформированы основные рекомендации для исследователей и врачей для проведения клинического анализа ходьбы. Описаны основные модели установки пассивных маркеров, применяемых в клиническом анализе походки пациентов с детским церебральным параличом. Отмечено, что IOR -Модель оптимально подходит для клинического анализа походки у пациента с низкой скоростью ходьбы при минимальной конфигурации системы (6 камер). Описывается методика моделирования Оксфордской стопы (Oxford foot model), которая позволяет детально отразить биомеханику движения различных отделов стопы во время локомоций.</p></abstract><trans-abstract xml:lang="en"><p>This paper presents a review on the methodology used to enable capturing pathological gait data via clinical video analysis which is used in diagnosis and treatment of individuals with functional disorders of the musculoskeletal system. Available literature sources were used to formulate recommendations for researchers and doctors in clinical study of walking and gait. Main patterns of placement of passive markers used in the clinical analysis of the gait in children with cerebral palsy were described. It was found that the IOR model is optimal for clinical analysis of the gait in patients that have low walking speed using a minimal capture system configuration (6 cameras). The method of Oxford Foot Model is described which is able to reflect in detail the biomechanics of foot parts during walking.</p></trans-abstract></article-meta></front><back><ref-list><title>References</title></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
